Inside diameter
Reconstruct the internal profile from measured points and determine inside diameter through circle fitting.
PIPE-END METROLOGY / pipeMatten
Inside diameter, outside diameter and local wall thickness, in one circular scan.
Move beyond isolated readings to a fuller dimensional picture.
HOW IT WORKS · INTERACTIVE 3D
See support, positioning and rotating measurement through a transparent pipe. Switch configurations to explore the different workflows.
Twin screws drive the scissor supports to raise the instrument. Once supported and positioned, the head performs a circular scan.
Reconstruct the internal profile from measured points and determine inside diameter through circle fitting.
Determine dimensions from the measured outer profile, rather than substituting nominal dimensions.
Review wall thickness around the section, including minimum, mean and maximum values.
MEASUREMENT
Angle and distance data describe the cross-section. Two sensors observe the inner and outer surfaces to support pipe-end inspection, process checks and matching analysis.
WORKFLOW
Connect the tablet wirelessly and establish the measurement reference with a suitable calibration ring.
Prepare the selected support configuration and position the head at the required section.
Start a circular scan from the tablet and review diameter and wall-thickness results.
WIRELESS CONTROL · BATTERY POWER
Connect over Wi-Fi for calibration, scanning and result review. The tablet brings the section profile and key dimensions together in one place.
CONFIGURATION
Select sensors, supports and calibration for the required dimensions, section locations and operating conditions.
Powered expansion and retraction reduce manual support adjustment. The modular configuration shares the measurement and control workflow.
Fixed support geometry without a lift drive. Placement and axial repositioning are manual; the support remains unchanged during scanning.
FAQ
Automatic supports expand and retract through a drive mechanism. Fixed supports retain their configured geometry for repeated measurements within a stable application. Both use a rotating measurement head.
No. Placement and withdrawal in the fixed-support animation represent manual handling. The support legs do not extend or retract.
Sections 20 mm or 100 mm from the pipe end are shown. Each scan covers one section; the application defines the final configuration and positioning.
Wall thickness is obtained from measured data, not nominal values. The selected sensor range, support configuration and calibration must suit the part.
Sensor and support configurations are selected for dimensions, section location, surface condition and operating cycle, with corresponding calibration and acceptance requirements.
START WITH YOUR APPLICATION
Tell us the dimensions, section location and accuracy requirement.
Configure the measurement around your application.